High Efficiency Horizontal (½ to 6 tons)
A-Vintage, ceiling-hung water source heat pumps are typically installed in hallways and other corridors, away from the occupied space for reduced sound and to allow easier service access.  Each unit provides heating and cooling to a specific space within the building.  A-Vintage units offer you the ability to achieve industry-leading energy efficiency in boiler/tower and geothermal applications. You can benefit from lower energy bills, higher energy rebates (where applicable) and A-Vintage units can help you earn points toward LEED® certification.  


Basic Features and Benefits:

  • Twelve units from ½ to 6 tons
  • Standard or geothermal operation
  • R-410A refrigerant
  • EER up to 21.0 and COP up to 5.6
  • ETL listed and AHRI/ISO 13256-1 certified for capacity and efficiency
  • Fully run-tested with water in both heating and cooling modes
  • Three speed PSC motor, sizes 012 and under, and electronically commutated motor (ECM), sizes 015 and larger, optimize efficiency throughout the unit operating range
  • Two-stage scroll compressor (sizes 024 to 072) optimizes efficiency throughout the operating range of the unit
  • HP-5 microprocessor-based control system including condensate overflow protection
  • Optional EPiC™ DDC controls provide for optimum performance using the control scheme or building management system and protocol of your choice
  • Heavy gauge steel cabinet maximizes durability and unit integrity while minimizing sound and vibration
  • Cabinet insulation provides superior thermal performance and reduces sound
  • Optional sound package for sensitive acoustic applications
  • Available with left or right hand water connections to match application requirements
  • Ample service access through removable panels simplifi es and encourages regular maintenance and service
  • Manufactured in the U.S.A. at our Holland, Michigan facility 

For more information, contact your local representative.

ISO 13256-1 Performance Data - Water Loop (Boiler Tower)

Unit Size

CFM 

GPM 

A-Vintage Horizotal - Water Loop (Boiler/Tower)1

Cooling

Heating

Qt 

Qs 

kW

EER 

Qt 

kW

COP 

006HHA

250

1.8

8,000

5,600

0.5

14.6

9,100

0.6

4.8

009HHA

340

2.6

10,100

7,300

0.7

15.1

11,200

0.7

4.7

012HHA

400

3.5

13,100

9,500

0.9

15.0

13,600

0.9

4.5

015HHA

520

4.5

16,700

12,400

0.9

18.9

16,700

0.9

5.6

018HHA

600

5.0

21,200

15,100

1.2

17.7

20,800

1.2

5.1

024HHA

800

6.5

27,800

20,700

1.6

17.2

28,700

1.7

4.9

030HHA

1000

9.0

33,200

24,300

1.9

17.1

37,600

2.2

4.9

036HHA

1200

10.5

41,400

30,300

2.4

17.2

40,600

2.5

4.7

042HHA

1400

12.0

47,100

35,100

2.8

16.6

47,100

3.1

4.5

048HHA

1600

14.0

50,900

39,600

2.9

17.4

58,900

3.5

5.0

060HHA

1900

17.0

66,600

48,500

3,7

17.8

72,100

4.4

4.8

072HHA

2100

20.0

75,800

56,300

4.7

16.0

81,800

5.6

4.3

1 Rated in accordance with ISO 13256-1 – Boiler/Tower.  Cooling capacity is based on 80.6°F db, 66.2°F wb (27/19°C) entering air temperature and 86°F (30°C) entering water temperature.  Heating capacity is based on 68°F (20°C) entering air temperature and 68°F (20°C) entering water temperature. For exact dimensional data, contact your local representative for a selection.

ISO 13256-1 Performance Data - Ground Loop (Geothermal)

Unit Size

CFM 

GPM 

A-Vintage Horizotal - Ground Loop (Geothermal)1

Cooling

Heating

Qt 

Qs 

kW

EER 

Qt 

kW

COP 

006HLA

250

1.8

8,400

6,000

0.5

16.1

5,200

0.5

3.0

009HLA

340

2.6

10,600

7,800

0.6

16.8

6,400

0.6

3.0

012HLA

400

3.5

13,800

9,700

0.8

16.7

7,900

0.8

2.9

015HLA

520

4.5

17,500

12,500

0.8

21.0

9,700

0.8

3.6

018HLA

600

5.0

22,300

15,300

1.1

19.8

12,000

1.1

3.2

024HLA

800

6.5

29,300

20,200

1.5

19.2

16,600

1.6

3.1

030HLA

1000

9.0

34,900

24,600

1.8

19.0

21,800

2.0

3.1

036HLA

1200

10.5

43,500

30,200

2.3

19.2

23,500

2.3

3.0

042HLA

1400

12.0

49,500

34,700

2.7

18.5

27,300

2.8

2.9

048HLA

1600

14.0

53,500

38,400

2.8

19.3

34,100

3.1

3.2

060HLA

1900

17.0

70,000

48,300

3.5

19.9

41,800

4.0

3.1

072HLA

2100

20.0

79,700

54,400

4.4

18.1

47,400

5.1

2.7

1 Rated in accordance with ISO 13256-1 – Ground Loop.  Cooling capacity is based on 80.6°F db, 66.2°F wb (27/19°C) entering air temperature and 77°F (25°C) entering water temperature.  Heating capacity is based on 68°F (20°C) entering air temperature and 32°F (0°C) entering water temperature. For exact dimensional data, contact your local representative for a selection.

GPM = Gallons Per Minute, EDB = Entering Dry Bulb (ºF), EWB = Entering  Wet Bulb (ºF), EWT = Entering Water Temperature (ºF),  Qt = Capacity Total (BTUH), Qs = Capacity Sensible (BTUH), EER = Energy Efficiency Ratio, COP = Coefficient of Performance

Mammoth, Inc.
13200 Pioneer Trail
Suite 150
Eden Prairie, Minnesota 55347-4125
USA
Map & Directions

TEL: 952.358.6600
FAX: 952.358.6700
www.mammoth-inc.com