Vertical (1 to 5 tons)

Water Source Heat Pump-VerticalU-vintage, floor-mounted water source heat pumps are typically installed in closets or small mechanical rooms near the occupied space.  Each single circuit unit provides cooling and heating for a specific zone within the building.  Mammoth offers some of the quietest water source heat pump units in the industry, allowing units to be located near the occupied space with minimal acoustic impact.  

Basic Features and Benefits:

  • Seven units from 1 to 5 tons
  • Standard or geothermal operation
  • R-410A refrigerant
  • EER up to 17.9 and COP rating to 4.8
  • Fully run-tested with water in both the heating and cooling modes 
  • Special construction for extremely quiet operation
  • Available with left or right hand water connections to match application requirements
  • ETL listed and ARI/ISO 13256-1 certified for capacity and efficiency
  • ASHRAE 90.1 compliant
  • Rotary and scroll compressors
  • Insulated cabinet with removable access panels for easy service
  • HP-5 microprocessor-based control system including condensate overflow protection
  • Optional EPiC™  DDC controls provide for optimum performance using the control scheme or building management system and protocol of your choice

For more information,  contact your local representative. 

ISO 13256-1 Performance Data - Water Loop (Boiler Tower)

Unit Size

CFM 

GPM 

U Vintage Vertical - Water Loop (Boiler/Tower)1

Cooling

Heating

Qt 

Qs 

kW

EER 

Qt 

kW

COP 

012VHU

440

3.3

11,600

8,200

0.9

13.5

12,900

0.8

4.5

024VHU

900

6.0

23,400

17,200

1.7

13.5

30,000

1.8

4.8

030VHU

1100

8.0

27,600

20,200

2.1

13.0

35,300

2.2

4.8

036VHU

1500

9.0

35,400

27,600

2.7

13.0

38,300

2.5

4.6

043VHU

1550

12.0

40,200

31,100

3.4

12.0

47,000

3.3

4.2

052VHU

1700

14.0

49,000

36,800

3.4

14.5

51,000

3.3

4.5

062VHU

1850

16.0

61,500

43,100

4.2

14.5

67,000

4.7

4.2

1 Rated in accordance with ISO 13256-1 – Boiler/Tower.  Cooling capacity is based on 80.6°F db, 66.2°F wb (27/19°C) entering air temperature and 86°F (30°C) entering water temperature.  Heating capacity is based on 68°F (20°C) entering air temperature and 68°F (20°C) entering water temperature. For exact dimensional data, contact your local representative for a selection.

ISO 13256-1 Performance Data - Ground Loop (Geothermal)

Unit Size

CFM 

GPM 

U Vintage Vertical - Ground Loop (Geothermal)1

Cooling

Heating

Qt 

Qs 

kW

EER 

Qt 

kW

COP 

012VLU

440

3.3

12,200

8,800

0.8

15.3

7,500

0.8

2.9

024VLU

900

6.0

24,300

18,400

1.6

15.0

17,400

1.6

3.1

030VLU

1100

8.0

28,600

21,400

2.0

14.4

20,400

2.0

3.1

036VLU

1500

9.0

37,100

29,400

2.6

14.5

22,200

2.2

2.9

043VLU

1550

12.0

43,200

33,500

3.1

14.1

28,300

2.9

2.9

052VLU

1700

14.0

53,300

40,100

3.0

17.9

31,100

2.9

3.2

062VLU

1850

16.0

64,800

46,300

3.9

16.6

40,000

4.17

2.8

1 Rated in accordance with ISO 13256-1 – Ground Loop.  Cooling capacity is based on 80.6°F db, 66.2°F wb (27/19°C) entering air temperature and 77°F (25°C) entering water temperature.  Heating capacity is based on 68°F (20°C) entering air temperature and 32°F (0°C) entering water temperature. For exact dimensional data, contact your local representative for a selection.

GPM = Gallons Per Minute, EDB = Entering Dry Bulb (ºF), EWB = Entering  Wet Bulb (ºF), EWT = Entering Water Temperature (ºF),  Qt = Capacity Total (BTUH), Qs = Capacity Sensible (BTUH), EER = Energy Efficiency Ratio, COP = Coefficient of Performance


Mammoth, Inc.
13200 Pioneer Trail
Suite 150
Eden Prairie, Minnesota 55347-4125
USA
Map & Directions

TEL: 952.358.6600
FAX: 952.358.6700
www.mammoth-inc.com
info@mammoth-inc.com